Hi Mike, Thank you for the information, I am looking to establish a company that shall be able to generate energy audit reports and recommendation specific for HVACR plantrooms, some of the services ill be producing are water analysis, air analys...
July 1
Hi Mike, just wandering, what is the actual services that TAB. Am currently contemplating to establish an energy audit company with specific concentration with the area of HVAC&R. I am hoping we could get acquainted and work out something for this...
June 29
Per book, laminar airflow may start at 2.5 diameter (as minimum) of the supply air duct (SAD) from the SA plenum. Hence, if we have 40" SAD then the sensor must be 100" away from the plenum. It is important that you know the equivalent diameter of...
February 22
congrats on being #100
February 16

Profile Information

Are you a technician, engineer, salesman, contractor, trader,employer?
Contractor/Company President
Please specify your field: refrigeration, kitchen, applied service, manufacturing.
HVAC Test & Balance
How long have you been in this trade?
30+ years HVAC, 25 years TAB

Mark Mimier's Blog

Mark Mimier

TAB Update #2

Last week, one of our clients requested that we test 3 paddle fans in one of their warehouses. By paddle fans, we are talking about the type of fan that mount to the ceiling in mga bahay. In this particular case, the fans were used to prevent air stratification during cold ambient temperatures. The 5 foot diameter fans were installed 18 ft. above the finished floor. Velocity measurements were taken approximately 1 foot below the fan discharge. Five readings were taken and averaged at the 3, 6, 9… Continue

Posted on February 2, 2009 at 8:30pm —

Mark Mimier

TAB Update #1

We are currently working on a Performing Arts addition to a local high school. The addition is served by one 36,000 CFM air handling unit. The unit has a supply and return fan along with hot and chilled water coils and mixing dampers for the economizer. Also at the discharge at the supply fan, there are sound attenuators. Also located in the air handling unit is a 5,900 CFM exhaust fan that provides general exhaust ventilation in the restrooms in the addition. A dedicated 6,500 CFM outside air f… Continue

Posted on January 13, 2009 at 9:30pm — 3 Comments

Mark Mimier

Test & Balance in the USA

Greetings from Frankfort, Indiana and everyone here at MGM Associates, Inc.

In the days (mga araw) ahead I hope to share with the Filipino HVAC community a description of projects we are working on along w/ pics and things we encounter as we perform TAB services for our clients here (dito) in central Indiana.

As for some background on who we are, MGM Associates was formed in 2006. I am the president of the company and have been in the HVAC field since 1973 when I started school at Milwaukee Ar… Continue

Posted on January 12, 2009 at 5:00pm — 2 Comments

Comment Wall (4 comments)

You need to be a member of HVAC/R PHILIPPINES to add comments!

Join this social network

At 9:05pm on July 1, 2009, Raymond Lavarias - Yorker said…
Hi Mike,

Thank you for the information, I am looking to establish a company that shall be able to generate energy audit reports and recommendation specific for HVACR plantrooms, some of the services ill be producing are water analysis, air analysis, motor vibration analysis., kWh consumption per KW./TON analysis, and so forth and so on.

I believe I could be able to learn from an expert like you, specially on the field oof Air Test and Water Test Analysis.

IlL email you more if its ok regarding some of the questions I have in mind regarding this idea.

Again, Thank You in Advance and God Bless.

Regards,

Raymond Lavarias
At 5:19am on April 24, 2009, Luna said…
At 1:56am on February 2, 2009, odette e. qeubrado said…
hi. im odette. maybe ur interested in applying as HVAC technician in saudi. Pls. txt me at 09284654939
At 6:43pm on January 12, 2009, Chillerman said…
Hi Mark, welcome to our network and thank you for joining us

Cheers!
 
 

LINKS

NBC HEADLINE NEWS
NBC DOCUMENTARIES
DISCOVERY CHANNEL
NATIONAL GEOGRAPHIC
HVAC TV



Forum

Martin Limjap

Emerson :US Multinational :Looking for HVAC Engineers 2 Replies

Started by Martin Limjap. Last reply by Martin Limjap 4 hours ago.

ronald dealca

centrifugal compressor 1 Reply

Started by ronald dealca. Last reply by roger longos Jul 7.

Jun Lope

We Repair & Rewind

Started by Jun Lope Jul 7.

Anna Jane Regina Bautro

HVAC Supervisor for OMAN 2 Replies

Started by Anna Jane Regina Bautro. Last reply by Anna Jane Regina Bautro Jul 7.

Events

Birthdays

There are no birthdays today

Badge

 

© 2009   Created by Chillerman

Badges  |  Report an Issue  |  Privacy  |  Terms of Service

You are Offline Sign in to chat!