HVAC/R PHILIPPINES

Filipino HVAC/R Community

Mark Mimier
  • Male
  • Frankfort, IN
  • United States
Share 
Share on Twitter
Share on Facebook

Mark Mimier's Friends

 

Mark Mimier's Page

Gifts Received

Gift

Mark Mimier has not received any gifts yet

Give Mark Mimier a Gift

Latest Activity

sir, iam sorry test & balance company pala po sorry again sir mark and sir mark what is the web site of TAB and how do i send my resume if ever thanks again pasensya na po...sorry again...
January 16
sir mark, hopefully you read my comments and by god will iam meet you in person and work with you at MGM Asso.and also add my knowledge more upon this field.iam exactly 10 years working as a HVAC/CHILLER technician know iam here in saudi arabia wor…
January 16
January 16
Mark Mimier and HVACERS are now friends
November 28, 2009
October 5, 2009
Mark Mimier and Kokz are now friends
October 5, 2009
September 24, 2009
Cheers and congratulation!
August 16, 2009

Profile Information

Are you a technician, engineer, salesman, contractor, trader,employer?
Contractor/Company President
Please specify your field: refrigeration, kitchen, applied service, manufacturing.
HVAC Test & Balance
How long have you been in this trade?
30+ years HVAC, 25 years TAB

Mark Mimier's Blog

Mark Mimier

TAB Update #3

In our very first post on 1/12/2009, we indicated that MGM Associates, Inc. was in the process of obtaining Test & Balance certification thru NEBB. We are pleased to announce that the process has been finalized and that we are proud members of this fine organization.

Posted on August 15, 2009 at 7:50am — 1 Comment

Mark Mimier

TAB Update #2

Last week, one of our clients requested that we test 3 paddle fans in one of their warehouses. By paddle fans, we are talking about the type of fan that mount to the ceiling in mga bahay. In this particular case, the fans were used to prevent air stratification during cold ambient temperatures. The 5 foot diameter fans were installed 18 ft. above the finished floor. Velocity measurements were taken approximately 1 foot below the fan discharge. Five readings were taken and averaged at the 3, 6, 9… Continue

Posted on February 3, 2009 at 9:30am —

Mark Mimier

TAB Update #1

We are currently working on a Performing Arts addition to a local high school. The addition is served by one 36,000 CFM air handling unit. The unit has a supply and return fan along with hot and chilled water coils and mixing dampers for the economizer. Also at the discharge at the supply fan, there are sound attenuators. Also located in the air handling unit is a 5,900 CFM exhaust fan that provides general exhaust ventilation in the restrooms in the addition. A dedicated 6,500 CFM outside air f… Continue

Posted on January 14, 2009 at 10:30am — 3 Comments

Mark Mimier

Test & Balance in the USA

Greetings from Frankfort, Indiana and everyone here at MGM Associates, Inc.

In the days (mga araw) ahead I hope to share with the Filipino HVAC community a description of projects we are working on along w/ pics and things we encounter as we perform TAB services for our clients here (dito) in central Indiana.

As for some background on who we are, MGM Associates was formed in 2006. I am the president of the company and have been in the HVAC field since 1973 when I started school at Milwaukee Ar… Continue

Posted on January 13, 2009 at 6:00am — 4 Comments

Comment Wall (6 comments)

You need to be a member of HVAC/R PHILIPPINES to add comments!

Join HVAC/R PHILIPPINES

At 9:33pm on January 16, 2010, roberto a.urzal jr. said…
sir thanks i meet u in hvac phil.can u help me find a vacancy to your company because my contract finish this 2010 of april.aim looking forward to read this.thanks and god bless...robert...
At 9:16am on September 24, 2009, Ruel Belo Alba said…
Hi Mark,

you mentioned that you went to the Philiippines, but are you based now in the Philippines and is MGM also based in the Philippines.

Our company MC Engineering Inc. install Air conditioning units for data centers and do TAB. we are interested if we can have MGM as our third party TAB.

Regards,

Ruel B. Alba
At 9:05am on July 2, 2009, Raymond L. said…
Hi Mike,

Thank you for the information, I am looking to establish a company that shall be able to generate energy audit reports and recommendation specific for HVACR plantrooms, some of the services ill be producing are water analysis, air analysis, motor vibration analysis., kWh consumption per KW./TON analysis, and so forth and so on.

I believe I could be able to learn from an expert like you, specially on the field oof Air Test and Water Test Analysis.

IlL email you more if its ok regarding some of the questions I have in mind regarding this idea.

Again, Thank You in Advance and God Bless.

Regards,

Raymond Lavarias
At 5:19pm on April 24, 2009, Luna said…
At 2:56pm on February 2, 2009, odette e. qeubrado said…
hi. im odette. maybe ur interested in applying as HVAC technician in saudi. Pls. txt me at 09284654939
At 7:43am on January 13, 2009, Chillerman said…
Hi Mark, welcome to our network and thank you for joining us

Cheers!
 
 
To download books, reference manuals and softwares, movies and many more, just proceed to download center.

To advertise on this network, just proceed to our Buy from 2CO counter.

2CheckOut.com Inc. (Ohio, USA) is an authorized retailer for goods and services provided by HVAC Philippines. Contact Chillerman for details.

Forum

Nestor Molato

how is the capacity slide inside the screw compressor function. 14 Replies

Started by Nestor Molato. Last reply by Nestor Molato 1 day ago.

Nestor Molato

??Procedures on Start up and Commissioning of Bitzer Screw Compressor CSH8561-125Y?? 9 Replies

Started by Nestor Molato. Last reply by Nestor Molato 1 day ago.

 

© 2010   Created by Chillerman

Badges  |  Report an Issue  |  Privacy  |  Terms of Service

Sign in to chat!